Kamoer 6-8L/min HLVP8 Diaphragm Vacuum Pump DC Motor Negative Pressure 0.098Mpa Low Noise In Parallal/Series for Lab and Beauty

Kamoer 6-8L/min HLVP8 Diaphragm Vacuum Pump DC Motor Negative Pressure 0.098Mpa Low Noise In Parallal/Series for Lab and Beauty

HLVP8-WB12 / China Mainland
₩203,454
제품 정보로 건너뛰기
Kamoer 6-8L/min HLVP8 Diaphragm Vacuum Pump DC Motor Negative Pressure 0.098Mpa Low Noise In Parallal/Series for Lab and Beauty
1/6

Kamoer 6-8L/min HLVP8 Diaphragm Vacuum Pump DC Motor Negative Pressure 0.098Mpa Low Noise In Parallal/Series for Lab and Beauty

₩203,454
Voltage
Ships From

SPECIFICATIONS

Application: Metering

Brand Name: kamoer

Certification: CE,RoHS

Diaphragm Vacuum Pump Flow: More than 360L/H(S); More than 480L/H(D)

Diaphragm Vacuum Pump Motor: Brushless/Brush motor

Diaphragm Vacuum Pump Voltage: 12V/24V

Diaphragm material: EPDM

Fuel: Electric

High-concerned chemical: None

Lifetime: HLVP8=6000H; HLVP-2-5000H

Model Number: HLVP8/HLVP8-2 Diaphragm Vacuum Pump

Negative pressure(Double head): More than -0.098Mpa

Negative pressure(Single head): More than -0.088Mpa(in series); More than -0.072Mpa(in parallel)

Noise: Less than 72dB

Origin: China Mainland

Positive pressure(Double head): More than 0.1Mpa

Positive pressure(Single head): More than 0.1Mpa(in parallel)

Power (W): Electric

Power Source: Electric

Pressure: Low Pressure

Standard or Nonstandard: Standard

Structure: Diaphragm Pump

Theory: Vacuum Pump

Usage: Water

6-8L/min HLVP8 Diaphragm Vacuum Pump

DC Motor Negative Pressure 0.098Mpa

★ Long life
★ Brushless motor
★ Wide application
★ Maintenance-free
★ Large flow
★ Chemical stability
★ Dry running


Basic Parameters

HLVP8-WB24/WB12

HLVP8-WB24-SHLVP8-WB12-S

Series

In Parallel

In Series

Effective flow L/min

8L/min

6L/min

Negative pressure

≥-0.07Mpa

≥-0.09Mpa

Positive pressure

≥0.1Mpa

≥0.1Mpa

Power

16W

16W

Noise

72dB

72dB

Control method

PWM; Fixed speed

PWM; Fixed speed

Net weight

300g

300g

Rated voltage

12V/24V

12V/24V

Motor type

Outer rotor brushlessmotor

Outer rotor brushlessmotor

Motor lifetime

≥6000H

≥6000 H

Applicable environment

Temperature range: 0℃~50℃; Relative humidity: <80%

Supplementary instructions

The above parameters are tested at standard atmospheric pressure, room temperature 25°C, and the medium is air.

Measured at a distance of 50cm under ambient noise of 35dB

The performance parameters of the product are affected by environmental conditions (air pressure, temperature, humidity, etc.), medium conditions (temperature, density, viscosity, chemical properties, etc.) and the load before and after the pump, so the above parameters may be different from the actual parameters.

Optional accessories

PU tube:ID4mmxOD6mm; 0.3m

Connector: Straight 3/32


Basic Parameters

HLVP8-B24-2-S

HLVP8-B12-2-S

HLVP8-C24-2-S

HLVP8-C12-2-S

Effective flow L/H

360L/H

360L/H

270L/H

270L/H

Negative pressure

≥0.098Mpa

≥0.098Mpa

≥0.098Mpa

≥0.098Mpa

Positive pressure

≥0.1Mpa

≥0.1Mpa

≥0.1Mpa

≥0.1Mpa

Power

18W

18W

12W

12W

Noise

75dB

75dB

75dB

75dB

Net weight

385g

385g

360g

360g

Rated voltage

12V/24V

12V/24V

12V/24V

12V/24V

Motor type

Brushless motor

Brushless motor

Brushless motor

Brushless motor

Motor lifetime

5000 H

5000 H

5000 H

5000 H

Applicable environment

Temperature range: 0℃~40℃; Relative humidity: <80%

Supplementary instructions

The above parameters are tested at standard atmospheric pressure, room temperature 25°C, and the medium is air.

Measured at a distance of 50cm under ambient noise of 35dB

The performance parameters of the product are affected by environmental conditions (air pressure, temperature, humidity, etc.), medium conditions (temperature, density, viscosity, chemical properties, etc.) and the load before and after the pump, so the above parameters may be different from the actual parameters.

Spare parts for 1 pump


1. Sealing ring 2. Valve 3. Diaphragm


Various Applications

# Automation
# Laboratory
# Medical Equipment
# Gas Analysis

Packing List

1 × HLVP8/HLVP8-2 (12V/24V; in parallel/in series).

More Details

Product Performance

▲ HLVP8 Diaphragm Vacuum Pump

Model

Flow

(L/H)

Negative Pressure

(MPa)

Positive Pressure

(MPa)

Noise

(dB)

HLVP8-WB12-S

≥360

≥ -0.09

Stall

≤72

HLVP8-WB12

≥480

≥ -0.07

≥0.1

≤72

HLVP8-WB24-S

≥360

≥ -0.09

Stall

≤72

HLVP8-WB24

≥480

≥ -0.07

≥0.1

≤72


▲ HLVP8-WB12-S Diaphragm Vacuum Pump

W-Outor rotors
B-brushless motor
12-12V
S-in series

▲ HLVP8-2 Diaphragm Vacuum Pump

Model

Flow

(L/H)

Negative Pressure

(MPa)

Positive Pressure

(MPa)

Noise

(dB)

HLVP8-B24-2-S

≥360

≥ -0.098

Stall

≤75

HLVP8-B12-2-S

≥360

≥ -0.098

Stall

≤75

HLVP8-C24-2-S

≥270

≥ -0.098

Stall

≤75

HLVP8-C12-2-S

≥270

≥ -0.098

Stall

≤75


▲ HLVP8-B24-2-S Diaphragm Vacuum Pump

B-brushless motor
24-24V
2-Double head
S-in series


Line Discription


Thread color

Red

line

Yellow

line

White

line

Black

line

Functions

Vcc

FG

PWM

GND

Description


Positive electrode

Speed feedback

Speed regulating

Negative electrode


HLVP8--In Parallel(Flow)

HLVP8--In Series(Flow)

HLVP8-B (Pressure flow curve)

HLVP8-C (Pressure flow curve)

Installation Dimensions

HLVP8(Single head)

HLVP8-2(Double head)

Contact us if any question.

We are always at your service!

Waiting for your order.



You may also like